Abstract

The GSH-1 is a 1970s-era hot cathode, neon-fill gas-discharge tube the Soviets manufactured for radar calibration. This is the second and final iteration of this project. My goal is to measure and identify the electrical noise spectrum, which is broadband in nature and produced by a combination of shot noise, thermal, and gas ionization factors. The intention is to try and identify the plasma striation frequency as well as predict and identify the plasma frequency. How will it appear? In what frequency?

Schematic

Schematic of the full instrument Schematic of the full instrument

Schematic of the logic level PCB Logic level PCB

Build Log

Day 1 — 10/15

The main issue in the circuit topology of the Plasma Entropy Source V.1 was the anode, where 200 VDC, 10 kVAC and the decoupling capacitors all met. The 200 VDC took the path of least impedance and traveled through the 10 kV strike line instead of through the tube. To combat this issue, I decided to essentially redesign the power supply. Instead of these three components meeting at one node, I removed the 10 kV strike voltage and opted for preliminary ionization through an external coil (capacitive coupling). I put the tube inside of an aluminum spring and connected one end of the 10 kV supply output to it. I got the positive column fully extended, but the tube won’t sustain on solely DC yet.

The positive column fully extended Cathode dark region

Day 2 — 10/17

I started working on the power supply. It’s imperative to this project that I minimize electrical noise, so I’m avoiding switching power supplies and am instead using a transformer I found in an old radio receiver. I need two or three 12 VDC and one 6 VDC. In order to filter mains ripple out, I put one 7500 µF or 8500 µF capacitor per output of half-wave rectifier. As predicted, the ripple is 60 Hz post-rectification. For whatever reason I noticed some higher frequency noise as well on my oscilloscope, the Vpp in the mV, so noise of relatively low amplitude. I added linear regulators (L7812) and 0.1 µF and 100 µF on the output. Now the noise is in the mV in amplitude.

Filter capacitors on the linear supply The linear supply, built around a transformer salvaged from an old radio receiver

Day 3 — 10/19

I finally got the GSH-1 tube to sustain on DC. This is how the day went.

At first, I couldn’t figure out exactly why it wasn’t working and why I was only getting 3 V across my 1 kΩ ballast — that’s 3 mA. For whatever reason there was practically no current passing through the tube. When I turned up the RF 10 kV module, the DC passing through increased exponentially. I figured this was because of charge carriers being added to the mix, the plasma becoming more excited and therefore more conductive. It was still far lower than I needed, however.

I decided to do some casual research and noticed an obvious flaw all of a sudden. On the cathode side, I didn’t tie one of the filament electrodes to the same ground plane as the 0 V coming from the DC boost module. They had to be tied in order for the electrons to properly flow from the cathode. I tied the two pins together — however, the tube still wouldn’t sustain. At this point I knew I was missing something, because this was defying logic. The only thing I noticed was that now, across my 1 kΩ ballast, I was reading 7 mA. A serious increase from 3 mA.

Building the driver Building the driver

I started troubleshooting. I’d turn the strike voltage input down as much as I could from my lab supply until the ionization would go out; I started at 12 V in and went down to 5 V, at which the RF 10 kV strike voltage module would go out. I noticed that with the decreasing RF, I could more easily see the effects of the DC boost module. At this time I had turned up the output voltage to 300 VDC, so the tube’s emissions were especially bright. Because I was only feeding 5 V to the RF 10 kV module, the ionization was mostly caused by the 300 VDC, yet it still needed the 10 kV strike on at all times to sustain.

I noticed there was a strange oscillation happening — the tube was blinking very quickly, at the same rate at which an LED on the DC boost was flickering. From this data I deduced that the supply was starved for current. I was right: across the input I read 9 V, and it needed anywhere from 12–24 V. I fed it 20 V and the tube finally sustained. What a beautiful and satisfying feeling it was, seeing the tube glow truly as intended for the first time.

The GSH-1 sustains at 293 VDC, 87 mA. At no less than 290 VDC will the tube sustain. Although it’s rated for 250 V, I assume that because it’s from the 1970s the pressure has changed, or maybe even helium atoms have penetrated the glass envelope over time — these factors causing the required voltage to rise. A favorite feature of mine in the tube’s emission is this little congregation of plasma on the cathode. It’s what I believe is the cathode dark zone. Either way, super cool to see.

Plasma congregating at the cathode The congregation of plasma at the cathode

Day 4 — 10/20

With the tube finally sustaining, I now had to see what the noise spectrum looked like. Unfortunately, all I have in terms of measurement methodology is a cheap handheld oscilloscope which doesn’t even have a frequency analyzer, but it’ll do for now. I connected to the anode of the tube, grounded the scope, and noticed a variety of electrical noise from 10 kHz all the way up to 300 kHz. I assume this is from the HV boost converter and that I was reading switching noise.

I designed an LC circuit at the output of the DC boost converter. It’s a low-pass filter with a cutoff frequency of 610 Hz. I put a 68 µF 500 V rated cap in series with a 10 mH inductor and read 2–6 kHz at the output, relatively steady. Seeing the semi-steady frequency noise on the output was satisfying; I successfully removed higher frequency noise, although I need to mitigate the noise further.

Day 5 — 10/25

I designed several filters to try and filter out the 3 kHz noise. Although I successfully filtered out the high ends, something was amiss — the math wasn’t ‘mathing’. My first LC filter (Day 4) wasn’t filtering out the 2–6 kHz noise despite the cutoff being set at 193 Hz.

F = 1/(2π√(0.01 × 68e-6)) = 193 Hz

I decided to design several more filters and test each one. I designed four total, including the original. The last one worked the best: a 68 µF cap going to ground, a 10 mH inductor in series, a 10,000 pF cap going to ground, a 1 kΩ 25 W ballast, another 10,000 pF to ground, and only then connected to the anode of the tube. This is essentially an LC and RC filter in series. Despite the unconventionality, it worked very well. So well, in fact, that I grew suspicious.

I was reading an extremely stable 3.02 kHz signal on the anode, in a warped sawtooth waveform. It was so stable I first assumed it was a relaxation oscillation set by the 1 kΩ ballast and 10,000 pF capacitor — however, the time constant worked out to 15 kHz, not 3 kHz. So I knew it wasn’t that.

Through all of this filtering, I realized this noise had to be occurring ‘downwind’ in the chain of components that is my instrument so far. The only possible noise source downwind is the tube itself, leading to an exciting epiphany: what if this was plasma striations I was measuring? It fit — a relatively low frequency oscillation which was stable. I had to know for sure.

An interesting thing I keep thinking about is how in Plasma Entropy Source V.1 I had a frequency spectrum set up in Python, and the peak with the most amplitude was around 3 kHz. And now I’m still seeing that, but with better methodology (e.g. filtering) and instrumentation — and I can see the waveform.

I needed to test my power supply (HV boost) directly, which is where it went comically wrong. I had to supply a load to the boost supply to test what switching noise it produced. I couldn’t use a resistor unless it was very high wattage, because it would burn off excessive heat. I had to get more creative, and used a halogen bulb — which is essentially a resistor anyway, just one in a vacuum.

Halogen bulb test Using a halogen bulb as a high-wattage load

I connected the bulb and fired up the converter. To my satisfaction the waveform was different: more sinusoidal and much higher frequency, moving around quite a bit but averaging around 200 kHz, which I assume was my switching noise. According to this logic, I can deduce the 3 kHz is coming from the tube itself.

Unfortunately, I didn’t account for how much current the converter was drawing — I was using rectifier diodes rated for 3 A. The diode eventually exploded, quite violently. Half-wave rectification was now destroyed, and a full amplitude sine wave of 20 V, most likely 26 V peak, was supplying the converter. Two capacitors exploded even more violently than the diode, and my discovery of potential neon plasma oscillations was now an afterthought.

Day 6 — 10/26

I forgot to mention: throughout testing and building the power supply for this tube, I taught myself KiCad, and have been preparing to order my first PCB.

The finished PCB Board layout in KiCad

Day 7 — 10/28

Whilst awaiting my PCB delivery, I had to be certain of what this 3 kHz waveform was. I started to collect some data, studying how the amplitude and dimensionality of the waveform changed with current and voltage. I want it to be plasma striations, but I cannot make a baseless claim without evidence.

I cranked the sustain voltage up and down, measuring the voltage across the resistor and calculating the current draw from that:

V / R  (V across R) = I

Here is my first small dataset.

Supply (V) Current (mA) Tube voltage (V)* Oscillation frequency (kHz) Amplitude (Vp-p)
272 67 205 4.20 4.20
285 85 200 2.89 7.30
290 96 194 2.88 8.00
295 109 186 3.02 9.00

* Tube voltage = supply − (current × 1 kΩ ballast). Measured at the anode with a handheld scope, AC-coupled.

There is a distinct correlation between current draw, amplitude, and frequency of the oscillation. Interestingly enough, I noticed that as the current and voltage rise, the frequency at which the tube is oscillating stays more stable — very stable at exactly 3.02 kHz. At lower voltage and current the frequency is less stable, rising and falling by 1 kHz. I also noticed the tube flicker off once due to being current starved, and I saw the waveform drop to 0 Hz. I need to collect more data.

Striations Striations

Simultaneously to this I also finished the power supply, adding terminals for easy installation, and 3D printed top and bottom pieces to hold the capacitors for easy consolidation and transportation.

Finished power supply The finished supply, with terminals and printed capacitor mounts

Day 8 — 11/8

Got my PCB in the mail. Haven’t tested the op-amp stage, but the power supply control works well.

Day 9 — 11/9

Really fun day today. Dr. Helio Takai and I took a look at the noise spectrum in the tube, and the near and far fields as well. We used a bipodal antenna and witnessed predominantly 0–50 kHz noise. More data certainly needs to be taken, but so far the tube is noisy in nature — not quite as broadband as the Soviets advertised. That’s alright, though, because they didn’t have frequency analyzers in the 1970s, so we forgive their falsehoods.

The antenna setup The antenna setup

Our methodology went as follows. We started out by setting up the antenna as close to the tube as possible, plugging the antenna into the oscilloscope and observing the frequency analyzer. We saw FM radio stations and environmental noise typical of an urban environment. We turned the tube on and off, sweeping from the low ends all the way up to 2 GHz. We couldn’t see anything, which was disappointing — however, I wondered whether the noise amplitude was just too low for the antenna to pick up.

I wrapped a wire around the tube, settling for inductively picking up the noise being emitted from the tube. I had hoped the proximity of our makeshift inductive coil would allow us to detect the noise if it was indeed there, just low in amplitude. It actually worked. We were able to see that the GSH-1 is inherently noisy in nature, even via inductive coupling. We first looked at the high ends and didn’t see much until we spotted a lot of noise at 60 MHz and below. Tube off versus on, below.

100mhz tube off

100mhz tube on

We noticed a change and we’re able to isolate that change to be around 60mhz, see below.

60mhz tube on

But it was really the low ends which lit up when the tube was ignited.

Spectrum with the tube off tube off

Spectrum with the tube on tube on

Day 10 - 11/11

Dr. Takai is helping me figure out what the plasma frequency of the tube would be. In order for him to do this, he must know the volumn of electrons moving throughout the tube. The variables needed are pressure, current, and diameter of the tube. The only unknown is pressure.

He hypothesizes the frequency to be somewhere in the 3.5ghz range, which means due to the sampling limit of the oscilloscope we were using (2.1ghz) we wouldn’t of seen it. I also have a feeling the amplitude is very small, and to get a reading of it I’m going to have to amplify the signal if there, and process it accordingly.

Day 11 - 11/13

I’ve been playing around today with coupling capacitors, and what the audio would sound like because of the significant amount of noise in the audio range. I started off by wiring a 68uF and 10nF cap in parallel, with a 100k resistor to ground, forming an RC filter with a very low cut off. To my amusement I accidently created a pulse tube - the caps filling up and dumping 300v into the tube, dumping 3.3 joules of energy according to my math. It pulses, and it’s quite entertaining to watch. I also did a little experiment and coupled the tube signal through the 10nF capacitor to a Darlington pair of two BJT transistors to add some gain to the signal, then sent that signal to a speaker. I didn’t need to amplify the signal because the 3khz sine had an amplitude of 7-10VPP. Out from the speaker came an annoying shrill 2-3khz sine as expected. I compared it to a verified 3khz sine wave, and it sounded identical - Dr. Takai told met to download the program Audacity in order to see if it’s a pure 3khz sine.

Day 12 - 11/16

I’ve started fabricating the sheet metal enclosure. Although the whole start up sequence; (filament, strike, sustain) would’ve been nice fully automated just as the V.1 was, I realized that for this application (V.2), which is solely instrumental, I prefer to have more autonomy over the workings/start-up of the tube. For example, I can choose to run it on just RF or run it without the filament on. There are more variables I have control over when there is a switch to control each one, as opposed to the alternative, which is a single switch, that starts the automated logic which starts the tube. Therefore, I’ve opted to not use the PCB, the logic board which starts the tube, and that I spent so much time on. If this instrument’s purpose was demonstrational, I would’ve opted for the PCB, but the purpose of this is to study the plasma noise spectrum, and discharge characteristics.